Crude Oil Storage Terminal



Sizing of two API 650 tanks with capacity of 100,000 bbl each, Pumping station for transfer of crude oil to Pipelines and re-circulating within tanks, LACT units for transfer of ownership.

Inputs from Client:

♦ Internal Floating Roof (IFR) Storage tanks designed with API-650 Standard

♦ Preliminary Inputs on plant layout

♦ LACT (Lease Automated Custody Transfer) Unit requirements

♦ Booster Pump capacity to pump into the Pipeline Pumps

♦ Fire Protection System

KED Scope of Work :

♦ Developed Process Design Basis document, Process Flow Diagram, Process and Instrumentation Diagram.

♦ Unit consisted of two 100,000 BBL storage capacity IFR tanks, 12 LACT (385 GPM) Units with capability to pump 8 units to each tank, two-3500 GPM Booster pumps to circulate and / or Pump into Pipeline pumps.

♦ Sizing of Equipment and prepared Datasheet .

♦ Equipment Piping Layout.

♦ Developed Fire Protection System as per NFPA guidelines .